Compatibility is a matrix, not a badge.

FHIR release support, server interoperability, profile coverage, and published validation evidence are separate questions. Records states each one explicitly.

Product contract reviewed 25 August 2026

FHIR release support

A public entry point accepting a version is not the same as a published conformance result for that version.

FHIR releasePublic entry pointsValidation statusPublished evidence
R4SupportedTestedHistorical archive and a dated September diagnostic comparison
R4BSupportedCompatibilityRelease identity and hl7.fhir.r4b.core#4.3.0 pin preserved
R5SupportedSupportedVersion-aware core and implementation-guide loading
R6AcceptedPreviewPinned hl7.fhir.r6.core#6.0.0-ballot4 base package

Evidence reviewed on 28 September 2026: the 21 September diagnostic run contains unresolved R4, R5, MII and EPS comparisons, and no completed precision measurement. Read the dated results and their limits before interpreting the historical archives as evidence for a current package.

R4 · Tested

What the status means

R4 support is package-specific. The 21 September diagnostic report retains two failed comparisons under explicit gate exceptions. Historical archives do not establish a current-package conformance score.

R4B · Compatibility

What the status means

The current engine uses the explicit R4 maintenance adapter internally; treat package-specific behavior as a compatibility question.

R5 · Supported

What the status means

Coverage depends on the exact package, terminology source and validation aspect. Four comparisons failed in the 21 September diagnostic run; historical results are not a current-package coverage claim.

R6 · Preview

Preview boundary

R6 findings retain an explicit limited-support status and must not be presented as production-equivalent coverage.

Compare the declared server surface with a concrete target.

Records turns the CapabilityStatement into a reviewable readiness result for a pinned target such as ISiK, IPS, IPA, or an EU Patient Summary lane.

ISiK readiness requirements with pass, warning, fail, and the explicit instance-validation boundary.

Test another requirement against the same resource.

Compare the same synthetic Patient against FHIR R4 and ISiK Patient 5.1.3. Inspect the patient-number requirement, add the MR identifier type, then verify the correction under the same ISiK profile.

Compare FHIR R4 with ISiK and correct the patient identifier

This compares an instance under selected requirements. It does not prove that one profile is compatible with another for every conforming instance.